FF109 Downlighter Covers
TENMAT FF109 Downlighter Covers are fire and acoustic rated covers or fire hoods designed to fire rate downlight fixtures and reinstate the performance of ceilings when penetrated by recessed downlights.
The covers are available in various sizes to suit a wide range of lighting products over and above those covered by fire rated downlights.
The covers are simple to install and can be retrofitted into position providing effective performance even if the downlight is removed and replaced.
The covers are ventilated to allow heat to disperse from the light but in the event of a fire the intumescent material expands to seal off the ceiling cut-out and vent holes.

For more information about Fire Rated Recessed Light Covers in the United States, please click here.

For more information about Downlight Protection Covers in Australia, please click here.
Applications
  • Fire Rating Recessed Downlights
  • Acoustic Protection of Downlights
  • Fire Rated Ceilings
  • Acoustic Rated Ceilings
  • Timber Ceiling / Floor
Properties
  • Fire Tested for up to 120 Minutes
  • Acoustically Tested
  • Simple to install
  • Ventilated
  • Cost effective
Fire Testing Approvals
Chiltern
opl ul2
Suspended Ceiling and Timber, Steel or Concrete Beam / Joist protected by plasterboard Assessment No.: CHILT / A02105 Rev B / Chiltern Int. Fire

Fire rated ceiling / floor systems protecting timber joists, steel joist systems and concrete floor: AS1530.4 Assessment No.: FAR 2032 / BRANZ Fire Rating: FRL 60 / 60 / 60

Acoustic Testing Approvals
FF109 Covers have undergone acoustic testing in separating and internal ceiling / floor
constructions and have been shown to reinstate acoustic insulation in line with
Approved Document E, following the fitting of downlights.
Certificate No.: 213942 / BRE
Regulations
Meets the requirements of UK Building Regulations Approved Documents B and E.